Kesalahan ini mungkin terlihat pada Perangkat Lunak Quartus® Prime Pro Edition saat memprogram file .sof ke Stratix® 10 FPGA - Transceiver TX SI Development Kit - DK-SI-1STX-E-A.
Untuk mengatasi kesalahan ini, Anda perlu memasukkan pengaturan SmartVID lengkap berikut ke dalam file QSF proyek Perangkat Lunak Quartus® Prime:
set_global_assignment -nama VID_OPERATION_MODE "PMBUS MASTER"
set_global_assignment -name PWRMGT_BUS_SPEED_MODE "100 KHZ"
set_global_assignment -name PWRMGT_SLAVE_DEVICE_TYPE LTM4677
set_global_assignment -nama PWRMGT_SLAVE_DEVICE0_ADDRESS 47
set_global_assignment -nama PWRMGT_SLAVE_DEVICE1_ADDRESS 48
set_global_assignment -nama PWRMGT_SLAVE_DEVICE2_ADDRESS 00
set_global_assignment -nama PWRMGT_SLAVE_DEVICE3_ADDRESS 00
set_global_assignment -nama PWRMGT_SLAVE_DEVICE4_ADDRESS 00
set_global_assignment -nama PWRMGT_SLAVE_DEVICE5_ADDRESS 00
set_global_assignment -nama PWRMGT_SLAVE_DEVICE6_ADDRESS 00
set_global_assignment -nama PWRMGT_SLAVE_DEVICE7_ADDRESS 00
set_global_assignment -nama PWRMGT_TRANSLATED_VOLTAGE_VALUE_UNIT VOLT
set_global_assignment -name PWRMGT_PAGE_COMMAND_ENABLE ON
set_global_assignment -name USE_PWRMGT_SCL SDM_IO14
set_global_assignment -name USE_PWRMGT_SDA SDM_IO11
set_global_assignment -name USE_CONF_DONE SDM_IO16
set_global_assignment -name USE_INIT_DONE SDM_IO0
set_global_assignment -name USE_SEU_ERROR SDM_IO13